Independent testing

Lab results

13 products were submitted to Canada Peptide Testing, an independent analytical laboratory in Canada, and tested by RP-HPLC-UV at the wavelength specified in each report against a ≥ 98.0% area purity specification. Every one conformed, the lowest measuring 98.84%. Each certificate below is the document as issued, and each can be verified at the laboratory rather than taken on our word.

Published certificates

Select any certificate to open the full-size PDF. You can also check each report directly with Canada Peptide Testing.

  • Retatrutide 20 mg vial

    Lot: PNP-RTT-2706

    Canada Peptide Testing certificate of analysis for Retatrutide 20 mg vial, report CPT-RETA-20-091226
    HPLC area purity
    99.31%
    Measured content
    20.24 mg
    Label claim
    20 mg
    Fill accuracy
    101.2% (at or over label)

    Report CPT-RETA-20-091226

  • Ipamorelin 10 mg vial

    Lot: PNP-IPA-2603

    Canada Peptide Testing certificate of analysis for Ipamorelin 10 mg vial, report CPT-IPA-10-091226
    HPLC area purity
    99.98%
    Measured content
    10.82 mg
    Label claim
    10 mg
    Fill accuracy
    108.2% (at or over label)

    Report CPT-IPA-10-091226

  • GHK-Cu 50 mg vial

    Assigned reference: PNP-GHK-1002

    Canada Peptide Testing certificate of analysis for GHK-Cu 50 mg vial, report CPT-GHKCU-50-091226
    HPLC area purity
    99.84%
    Measured content
    40.8 mg
    Label claim
    50 mg
    Fill accuracy
    81.6% (under label)

    Report CPT-GHKCU-50-091226

  • MOTS-c 40 mg vial

    Lot: PNP-MOT-1002

    Canada Peptide Testing certificate of analysis for MOTS-c 40 mg vial, report CPT-MOTS-40-091226
    HPLC area purity
    99.74%
    Measured content
    42.2 mg
    Label claim
    40 mg
    Fill accuracy
    105.5% (at or over label)

    Report CPT-MOTS-40-091226

  • BPC-157 10 mg vial

    Assigned reference: PNP-BPC-1002

    Canada Peptide Testing certificate of analysis for BPC-157 10 mg vial, report CPT-BPC-10-091226
    HPLC area purity
    99.71%
    Measured content
    10.65 mg
    Label claim
    10 mg
    Fill accuracy
    106.5% (at or over label)

    Report CPT-BPC-10-091226

  • KPV 10 mg vial

    Lot: PNP-KPV-2611

    Canada Peptide Testing certificate of analysis for KPV 10 mg vial, report CPT-KPV-10-091226
    HPLC area purity
    99.32%
    Measured content
    11.36 mg
    Label claim
    10 mg
    Fill accuracy
    113.6% (at or over label)

    Report CPT-KPV-10-091226

  • NAD+ 500 mg vial

    Lot: PNP-NAD-2615

    Canada Peptide Testing certificate of analysis for NAD+ 500 mg vial, report CPT-NAD-500-091226
    HPLC area purity
    99.27%
    Measured content
    483.5 mg
    Label claim
    500 mg
    Fill accuracy
    96.7% (under label)

    Report CPT-NAD-500-091226

  • Tesamorelin 20 mg vial

    Lot: PNP-TES-2614

    Canada Peptide Testing certificate of analysis for Tesamorelin 20 mg vial, report CPT-TESA-20-091226
    HPLC area purity
    99.04%
    Measured content
    20.34 mg
    Label claim
    20 mg
    Fill accuracy
    101.7% (at or over label)

    Report CPT-TESA-20-091226

  • CJC-1295 (mod GRF 1-29) 10 mg vial

    Lot: PNP-CJC-2604

    Canada Peptide Testing certificate of analysis for CJC-1295 (mod GRF 1-29) 10 mg vial, report CPT-CJCN-10-091226
    HPLC area purity
    99.12%
    Measured content
    10.34 mg
    Label claim
    10 mg
    Fill accuracy
    103.4% (at or over label)

    Report CPT-CJCN-10-091226

  • PT-141 10 mg vial

    Assigned reference: PNP-PT141-1002

    Canada Peptide Testing certificate of analysis for PT-141 10 mg vial, report CPT-PT141-10-091226
    HPLC area purity
    99.18%
    Measured content
    10.73 mg
    Label claim
    10 mg
    Fill accuracy
    107.3% (at or over label)

    Report CPT-PT141-10-091226

  • SS-31 10 mg vial

    Assigned reference: PNP-SS31-1002

    Canada Peptide Testing certificate of analysis for SS-31 10 mg vial, report CPT-SS31-10-091226
    HPLC area purity
    99.46%
    Measured content
    10.28 mg
    Label claim
    10 mg
    Fill accuracy
    102.8% (at or over label)

    Report CPT-SS31-10-091226

  • Thymosin Alpha-1 10 mg vial

    Lot: PNP-TA1-2619

    Canada Peptide Testing certificate of analysis for Thymosin Alpha-1 10 mg vial, report CPT-TA1-10-091226
    HPLC area purity
    98.91%
    Measured content
    9.94 mg
    Label claim
    10 mg
    Fill accuracy
    99.4% (under label)

    Report CPT-TA1-10-091226

  • TB-500 10 mg vial

    Lot: PNP-TB5-2612

    Canada Peptide Testing certificate of analysis for TB-500 10 mg vial, report CPT-TB500-10-091226
    HPLC area purity
    98.84%
    Measured content
    10.41 mg
    Label claim
    10 mg
    Fill accuracy
    104.1% (at or over label)

    Report CPT-TB500-10-091226

What this page does not cover

These 13 certificates cover the vial sizes named on them and the lots or assigned references named on them. They are not a statement about the rest of the catalogue, about other vial sizes of the same compound, or about lots shipped before 2026-09-12. For peptide lots not listed here, manufacturer QC documentation may be available on request — a different document, from the manufacturer’s own laboratory, which we do not describe as independent. Semax, Selank and Tirzepatide COAs are temporarily unavailable. Bacteriostatic water does not have a COA.

Request a certificate for your lot →

Questions

Who tested these products?
Canada Peptide Testing, an independent analytical laboratory in Canada. Pure North submitted sealed vials as a paying client on 2026-09-04; they were tested on 2026-09-09 and reported on 2026-09-12. Each certificate carries its own report number and verification key, and can be checked at the laboratory's own record rather than taken from us.
Which products have an independent certificate?
13 currently published: Retatrutide 20 mg vial, Ipamorelin 10 mg vial, GHK-Cu 50 mg vial, MOTS-c 40 mg vial, BPC-157 10 mg vial, KPV 10 mg vial, NAD+ 500 mg vial, Tesamorelin 20 mg vial, CJC-1295 (mod GRF 1-29) 10 mg vial, PT-141 10 mg vial, SS-31 10 mg vial, Thymosin Alpha-1 10 mg vial, TB-500 10 mg vial. Only the reports listed here are currently available on this site. A published report does not establish coverage for other sizes or lots.
What is actually measured?
Area purity by RP-HPLC-UV at the wavelength specified in each report against a ≥ 98.0% area purity specification, and content (mass) against a working standard. That is the whole panel. There is no mass-spectrometry identity run, no endotoxin or LAL figure, no water content and no related-substances breakdown on these certificates. Where you see those on another vendor's lab card, it is a different test that we have not had done.
Why publish fill accuracy?
Because the certificate publishes it, and the certificate is one click away. Fill accuracy is measured content against the label claim: over 100% means the vial held more than it claimed, under 100% means less. For example, GHK-Cu 50 mg measured 40.80 mg, 81.6% of label. Showing the good numbers and hiding that one would make every other number on this page worth less.
How do I check a certificate is real?
Every certificate carries a report number and a verification key, and links to the issuing laboratory's own record for that document. Check it there. A certificate that only exists on the vendor's own website is evidence about the vendor, not about the vial.
What about the manufacturer's certificate?
Manufacturer QC may be available on request for other peptide lots and is not independent. Semax, Selank and Tirzepatide COAs are temporarily unavailable. Email purenorthpeptides@proton.me with the batch number printed on your vial and customer service can confirm the available documentation and its scope for your lot. Bacteriostatic water does not have a COA.

For laboratory research use only. Past lots and how they are handled: certificate archive.